Surface Water Drainage and Backflow Protection
Surface water drainage and backflow protection cover the routing of rainwater away from a building together with technical safeguards that prevent sewage backing up into low-lying parts of a building.
Hazard picture
Public sewers are sized for a statistically recurring, limited rainfall event; during heavy rain or network overload, sewage can be pushed back towards a building. Drainage points below the governing backflow level, such as those in basements, are particularly exposed, as are surfaces with inadequate surface drainage where rainwater pools in front of entrances and light wells.
Protection measures
All drainage points below the backflow level should in principle be drained via a sewage lifting station; backflow valves can only serve as an alternative where the served area is of minor use and a gradient to the sewer exists. A plot’s surface drainage – gradients, channels, infiltration areas – must be designed to discharge water without damage even in heavy rain, and critical entrances are additionally protected with raised thresholds.
Insurance relevance
Backflow damage is a frequently underestimated form of water damage, as it can occur regardless of a building’s distance from a watercourse. Many property policy wordings explicitly exclude backflow losses where no functioning backflow protection is installed, making evidence of code-compliant protection relevant to the scope of cover.
Standards and codes
- SIA 190 – Sewer Systems