Risk Attribute

Fire Compartmentation

Expert-reviewed Updated: 2026-09-03 Expert-reviewed: 2026-09-04 (Guido Hesse, Hesse Group Holding AG) Version 0.1.0

Fire compartmentation records how a building is subdivided into fire-resistant sections, and is queried in property proposal forms to assess how effectively a fire can be contained before it spreads.

Category
Building
Data type
Enumeration
Risk drivers
Severity, Accumulation
Underwriting impact
Premium, Sublimit, Condition/Warranty

Typical proposal-form questions

  • Is the building subdivided into fire compartments, and what is the maximum compartment area or fire-resistance rating (e.g. EI 90, REI 120)?
  • Are firewalls carried through the full height and depth of the building, including roof and basement levels?
  • Are openings in fire-separating walls (doors, ducts, cable penetrations) fitted with fire-rated closures and dampers?

Evidence

  • Fire safety concept or compartmentation plan
  • Building permit documentation
  • Risk engineering survey report

Why it matters for underwriting

Fire compartmentation determines how large an area a single fire event can affect before fire-resistant construction stops or slows its spread. It is the primary structural counterpart to active protection such as sprinklers: even a well-sprinklered building can suffer a large loss if compartment walls are undersized, breached by unsealed openings, or do not extend fully through roof voids and risers. Underwriters use declared compartment size and rating to estimate the maximum single-event loss and to set accumulation limits relative to the sum insured at a location.

Capturing the attribute and evidence

Proposal forms ask whether the building is compartmentalised, the maximum area of a single compartment, and the fire-resistance rating of separating walls and floors. The fire safety concept, compartmentation plan and, for larger risks, a risk engineering survey confirm not only the design rating but also whether openings such as doors, cable and pipe penetrations are properly fire-stopped, since unsealed penetrations are a common cause of compartmentation failure in practice.

Effect on coverage, premium and conditions

Well-defined, adequately rated compartments with properly sealed openings support lower premium rates and higher single-location sublimits. Large undivided areas, compartment walls that stop short of the roof deck, or evidence of unsealed penetrations typically trigger rate loadings, reduced sublimits on accumulation, or a condition requiring remediation of identified compartmentation gaps within a defined period.

Mitigation measures

Where compartmentation is inadequate, insurers typically recommend extending fire-resistant walls to the required rating and full building depth, fire-stopping all service penetrations, fitting self-closing fire doors and dampers, and periodically inspecting compartment integrity.