  "id": "riskg-switchgear-protection",
  "type": "risk-guideline",
  "languages": {
    "en": {
      "id": "riskg-switchgear-protection",
      "lang": "en",
      "type": "risk-guideline",
      "title": "Switchgear",
      "shortDefinition": "Switchgear distributes and protects electrical power in buildings and industrial plants; contact ageing, mis-coordinated protective devices or overload are among the most frequent causes of electrical fires.",
      "synonyms": [
        "Low-voltage switchgear",
        "Distribution switchboard"
      ],
      "linesOfBusiness": [
        "Property",
        "Engineering"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Security",
        "Fire protection"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-electrical-installations",
          "riskg-arc-flash",
          "riskg-thermography"
        ],
        "partOf": [],
        "appliesTo": [
          "cov-property-all-risks",
          "cov-maschinenversicherung"
        ],
        "regulatedBy": [],
        "relevantFor": [],
        "insurableVia": [],
        "mitigatedBy": [],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": null,
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "VdS 6022 – Guidance on Thermography-Suitable Design of Switchgear"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-01",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-01T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/en/knowledge/risk-engineering/switchgear/",
      "alternateUrl": "https://hgh.ch/lexikon/de/wissen/risk-engineering/schaltanlagen/",
      "body": "## Design and hazard\n\nSwitchgear concentrates incoming supply, distribution and protective devices of an electrical installation in a confined space. Ageing screw and plug-in contacts, ingress of moisture or dust, and thermally overloaded busbars produce transition resistances that heat up unnoticed and, in the worst case, lead to arc flashes or fires. Protective devices that are not coordinated to recognised design standards can also fail to isolate a fault selectively, letting it affect the whole installation instead.\n\n## Protective measures\n\nKey measures are compliance with recognised construction standards for switchgear assemblies, a documented selectivity study of the upstream protective devices, and periodic inspection through visual checks, torque verification of connections and thermographic scanning under operating load. A thermography-friendly design – accessible inspection points, suitable viewing windows – substantially eases in-service checks and is increasingly recommended by loss prevention bodies.\n\n## Insurance relevance\n\nSwitchgear is a priority inspection item during technical risk surveys, since it can be both the origin of a fire and a weak point for business interruption. Documented maintenance and thermography programmes, together with a traceable protection coordination study, have a favourable effect on risk classification."
    },
    "de": {
      "id": "riskg-switchgear-protection",
      "lang": "de",
      "type": "risk-guideline",
      "title": "Schaltanlagen",
      "shortDefinition": "Schaltanlagen verteilen und schützen elektrische Energie in Gebäuden und Industrieanlagen; Kontaktalterung, Fehlkoordination von Schutzorganen oder Überlastung zählen zu den häufigsten Ursachen elektrischer Brände.",
      "synonyms": [
        "Niederspannungsschaltanlage",
        "Verteileranlage"
      ],
      "linesOfBusiness": [
        "Sach",
        "Technische Versicherung"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Sicherheitstechnik",
        "Brandschutz"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-electrical-installations",
          "riskg-arc-flash",
          "riskg-thermography"
        ],
        "partOf": [],
        "appliesTo": [
          "cov-property-all-risks",
          "cov-maschinenversicherung"
        ],
        "regulatedBy": [],
        "relevantFor": [],
        "insurableVia": [],
        "mitigatedBy": [],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": null,
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "VdS 6022 – Thermografiegerechter Aufbau von Schaltanlagen"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-01",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-01T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/de/wissen/risk-engineering/schaltanlagen/",
      "alternateUrl": "https://hgh.ch/lexikon/en/knowledge/risk-engineering/switchgear/",
      "body": "## Aufbau und Gefährdung\n\nSchaltanlagen bündeln Einspeisung, Verteilung und Schutzorgane einer elektrischen Anlage auf engem Raum. Gerade dort führen gealterte Schraub- und Steckkontakte, Feuchte- oder Staubeintrag und thermisch überlastete Sammelschienen zu Übergangswiderständen, die sich unbemerkt aufheizen und im ungünstigen Fall zu Störlichtbögen oder Bränden führen. Nicht normgerecht koordinierte Schutzorgane verhindern zudem, dass ein Fehler selektiv abgeschaltet wird, statt die gesamte Anlage zu betreffen.\n\n## Schutzmassnahmen\n\nMassgeblich sind die Einhaltung anerkannter Baunormen für Schaltgerätekombinationen, eine dokumentierte Selektivitätsplanung der vorgeschalteten Schutzorgane sowie eine periodische Inspektion mittels Sichtkontrolle, Drehmomentprüfung der Anschlüsse und Thermografie unter Betriebslast. Ein thermografiegerechter konstruktiver Aufbau – zugängliche Prüfstellen, geeignete Sichtfenster – erleichtert die Kontrolle im Betrieb erheblich und wird von Schadenverhütungsstellen zunehmend empfohlen.\n\n## Versicherungsrelevanz\n\nSchaltanlagen zählen bei der technischen Risikobesichtigung zu den priorisierten Prüfobjekten, da sie sowohl Brandausgangsort als auch Schwachstelle bei Betriebsunterbrechungen sein können. Dokumentierte Wartungs- und Thermografieprogramme sowie eine nachvollziehbare Schutzkoordination wirken sich günstig auf die Risikoeinstufung aus."
    }
  }
}