  "id": "riskg-fire-stopping",
  "type": "risk-guideline",
  "languages": {
    "en": {
      "id": "riskg-fire-stopping",
      "lang": "en",
      "type": "risk-guideline",
      "title": "Fire Stopping of Service Penetrations",
      "shortDefinition": "Fire stopping seals the openings made by cables, pipes and ventilation ducts through fire-separating elements so that their fire resistance is not undermined by open gaps.",
      "synonyms": [
        "Firestop",
        "Penetration seal"
      ],
      "linesOfBusiness": [
        "Property"
      ],
      "jurisdictions": [
        "EU",
        "Global"
      ],
      "tags": [
        "Fire protection",
        "Loss prevention"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-fire-doors",
          "riskg-fire-compartmentation"
        ],
        "partOf": [
          "riskg-fire-protection-concept"
        ],
        "appliesTo": [
          "cov-property-all-risks"
        ],
        "regulatedBy": [],
        "relevantFor": [],
        "insurableVia": [],
        "mitigatedBy": [],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": null,
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "VdS 3536 – Commentary on the Model Guideline on Fire Protection Requirements for Service Installations (MLAR)"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-01",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-01T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/en/knowledge/risk-engineering/fire-stopping-of-service-penetrations/",
      "alternateUrl": "https://hgh.ch/lexikon/de/wissen/risk-engineering/abschottung-leitungsdurchfuehrungen/",
      "body": "## The problem\n\nCable routes, pipework and ventilation ducts have to pass through virtually every separating wall and floor in a building. Each of these penetrations is a potential weak point: unsealed gaps act like chimneys, allowing fire and smoke to spread into adjoining compartments within minutes, even where the wall itself has a high fire resistance rating.\n\n## Technical execution\n\nFire stopping systems – mortars, pillows, collars, foams or boards – are tested and approved for specific manufacturers and must be installed exactly as approved, matching the type, diameter and insulation of the services passing through. Cables installed later without proper re-sealing are among the most common causes of ineffective compartmentation in existing buildings.\n\n## Insurance relevance\n\nBecause fire stops are usually concealed once construction is complete, risk engineers require installation and test certificates as well as documentation of any subsequent work on cable routes. Missing or improperly installed fire stops are among the most frequently identified deficiencies in property risk surveys and are routinely raised as improvement recommendations."
    },
    "de": {
      "id": "riskg-fire-stopping",
      "lang": "de",
      "type": "risk-guideline",
      "title": "Abschottung von Leitungsdurchführungen",
      "shortDefinition": "Die Abschottung von Leitungsdurchführungen verschliesst die Durchbrüche von Kabeln, Rohren und Lüftungsleitungen durch brandabschnittsbildende Bauteile, damit deren Feuerwiderstand nicht durch offene Spalten unterlaufen wird.",
      "synonyms": [
        "Brandschutzabschottung",
        "Fire Stopping"
      ],
      "linesOfBusiness": [
        "Sach"
      ],
      "jurisdictions": [
        "EU",
        "Global"
      ],
      "tags": [
        "Brandschutz",
        "Schadenverhütung"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-fire-doors",
          "riskg-fire-compartmentation"
        ],
        "partOf": [
          "riskg-fire-protection-concept"
        ],
        "appliesTo": [
          "cov-property-all-risks"
        ],
        "regulatedBy": [],
        "relevantFor": [],
        "insurableVia": [],
        "mitigatedBy": [],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": null,
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "VdS 3536 – Kommentar zur Muster-Richtlinie über brandschutztechnische Anforderungen an Leitungsanlagen (MLAR)"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-01",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-01T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/de/wissen/risk-engineering/abschottung-leitungsdurchfuehrungen/",
      "alternateUrl": "https://hgh.ch/lexikon/en/knowledge/risk-engineering/fire-stopping-of-service-penetrations/",
      "body": "## Problemstellung\n\nKabeltrassen, Rohrleitungen und Lüftungskanäle müssen praktisch jede raumabschliessende Wand und Decke eines Gebäudes durchdringen. Jede dieser Durchführungen ist eine potenzielle Schwachstelle: Ungeschlossene Spalten wirken wie Kamine und lassen Feuer und Rauch in Windeseile in benachbarte Brandabschnitte übertreten, selbst wenn die Wand selbst hoch feuerwiderstandsfähig ausgeführt ist.\n\n## Technische Ausführung\n\nAbschottungssysteme – Brandschutzmörtel, -kissen, -manschetten, -schäume oder -platten – werden herstellerspezifisch geprüft und zugelassen und müssen exakt nach Zulassung mit den jeweiligen Leitungsarten, -durchmessern und Dämmstoffen kombiniert werden. Nachträglich verlegte Kabel ohne fachgerechte Nachabschottung sind eine der häufigsten Ursachen für unwirksame Brandabschnitte in bestehenden Gebäuden.\n\n## Versicherungsrelevanz\n\nDa Abschottungen nach Fertigstellung meist verdeckt und nicht mehr sichtbar sind, verlangen Risk Engineers Ausführungs- und Prüfnachweise sowie Dokumentation nachträglicher Eingriffe an Leitungstrassen. Fehlende oder unsachgemässe Abschottungen zählen zu den am häufigsten festgestellten baulichen Mängeln bei Sachrisikobesichtigungen und werden regelmässig als Verbesserungsempfehlung aufgenommen."
    }
  }
}