  "id": "riskg-data-center-risk",
  "type": "risk-guideline",
  "languages": {
    "en": {
      "id": "riskg-data-center-risk",
      "lang": "en",
      "type": "risk-guideline",
      "title": "Data Centres – Risk and Loss Prevention",
      "shortDefinition": "Data centres combine a very high concentration of asset value in a small footprint with extreme sensitivity to business interruption, since even brief outages of power or cooling can trigger far-reaching consequential losses for customers.",
      "synonyms": [
        "Data center risk",
        "IT room risk"
      ],
      "linesOfBusiness": [
        "Property"
      ],
      "jurisdictions": [
        "EU",
        "Global"
      ],
      "tags": [
        "Fire protection",
        "Risk assessment",
        "Business interruption"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-emergency-power",
          "riskg-cable-fire-risks",
          "riskg-oxygen-reduction"
        ],
        "partOf": [],
        "appliesTo": [
          "cov-property-all-risks",
          "cov-elektronikversicherung",
          "cov-business-interruption"
        ],
        "regulatedBy": [],
        "relevantFor": [],
        "insurableVia": [],
        "mitigatedBy": [],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": null,
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "VdS 6003: Fire Protection Requirements for IT Rooms and Data Centres"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-01",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-01T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/en/knowledge/risk-engineering/data-centre-risk/",
      "alternateUrl": "https://hgh.ch/lexikon/de/wissen/risk-engineering/rechenzentren-risiken/",
      "body": "## Risk drivers\n\nData centres concentrate very high asset values in a small footprint in the form of servers, network equipment and redundant cooling and power supply systems. Unlike most other commercial properties, however, the primary concern at data centres is not property damage but business interruption: even a brief outage of cooling or uninterruptible power supply can cause data loss and downtime for numerous customers simultaneously. The dense cabling under raised floors and in cable risers also represents a substantial concealed fire load.\n\n## Protection measures\n\nKey measures include a gaseous or oxygen-reduction extinguishing system suited to IT spaces rather than water-based systems, very early fire detection using aspirating smoke detectors, redundant cooling and power supply paths built to recognised availability classes, and strict separation of IT floor areas from ancillary rooms with a higher fire load such as storage or battery rooms. A data centre's availability class largely determines the degree of redundancy required.\n\n## Insurance relevance\n\nFor property and business interruption cover of data centres, the duration of downtime after an event is often more significant than the pure replacement cost of the hardware, since customer contracts frequently include strict availability guarantees. Insurers reviewing the risk pay particular attention to the redundancy of critical supply paths and the suitability and maintenance of extinguishing systems for electronic equipment."
    },
    "de": {
      "id": "riskg-data-center-risk",
      "lang": "de",
      "type": "risk-guideline",
      "title": "Rechenzentren – Risiken und Schadenverhütung",
      "shortDefinition": "Rechenzentren verbinden eine sehr hohe Wertkonzentration auf kleiner Fläche mit extremer Betriebsunterbrechungsempfindlichkeit, da bereits kurze Ausfälle der Stromversorgung oder Kühlung weitreichende Folgeschäden bei Kunden auslösen können.",
      "synonyms": [
        "Data-Center-Risiko",
        "IT-Raum-Risiko"
      ],
      "linesOfBusiness": [
        "Sach"
      ],
      "jurisdictions": [
        "EU",
        "Global"
      ],
      "tags": [
        "Brandschutz",
        "Risikobewertung",
        "Betriebsunterbrechung"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-emergency-power",
          "riskg-cable-fire-risks",
          "riskg-oxygen-reduction"
        ],
        "partOf": [],
        "appliesTo": [
          "cov-property-all-risks",
          "cov-elektronikversicherung",
          "cov-business-interruption"
        ],
        "regulatedBy": [],
        "relevantFor": [],
        "insurableVia": [],
        "mitigatedBy": [],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": null,
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "VdS 6003: Brandschutztechnische Anforderungen an IT-Räume und Rechenzentren"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-01",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-01T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/de/wissen/risk-engineering/rechenzentren-risiken/",
      "alternateUrl": "https://hgh.ch/lexikon/en/knowledge/risk-engineering/data-centre-risk/",
      "body": "## Risikotreiber\n\nRechenzentren konzentrieren auf kleiner Fläche sehr hohe Sachwerte in Form von Servern, Netzwerktechnik und redundanter Klima- und Stromversorgungstechnik. Anders als bei den meisten anderen Gewerbeimmobilien steht bei Rechenzentren jedoch nicht der Sachschaden im Vordergrund, sondern die Betriebsunterbrechung: Schon ein kurzzeitiger Ausfall von Kühlung oder unterbrechungsfreier Stromversorgung kann zu Datenverlust und Ausfällen bei zahlreichen Kunden gleichzeitig führen. Die dichte Verkabelung unter Doppelböden und in Kabelschächten stellt zudem eine erhebliche verdeckte Brandlast dar.\n\n## Schutzmassnahmen\n\nZu den zentralen Massnahmen zählen eine für IT-Räume geeignete Gaslösch- oder Sauerstoffreduzierungsanlage anstelle wasserbasierter Systeme, eine sehr frühzeitige Branddetektion mittels Ansaugrauchmeldern, redundante Kühlungs- und Stromversorgungspfade nach anerkannten Verfügbarkeitsklassen sowie eine strikte Trennung von IT-Flächen und Nebenräumen mit höherer Brandlast wie Lagern oder Batterieräumen. Die Verfügbarkeitsklasse eines Rechenzentrums bestimmt massgeblich den Grad der erforderlichen Redundanz.\n\n## Versicherungsrelevanz\n\nFür die Sach- und Betriebsunterbrechungsversicherung von Rechenzentren ist die Betriebsunterbrechungsdauer nach einem Ereignis oft bedeutsamer als die reine Wiederbeschaffungssumme der Hardware, da Verträge mit Kunden häufig strenge Verfügbarkeitsgarantien vorsehen. Versicherer prüfen bei der Risikobesichtigung insbesondere die Redundanz kritischer Versorgungspfade sowie die Eignung und Wartung der Löschtechnik für elektronische Anlagen."
    }
  }
}