{
  "id": "ra-safe-security-rating",
  "type": "risk-attribute",
  "languages": {
    "en": {
      "id": "ra-safe-security-rating",
      "lang": "en",
      "type": "risk-attribute",
      "title": "Safe and Mechanical Security Rating",
      "shortDefinition": "Safe and mechanical security rating records the certified resistance grade of a safe, strongroom or vault used to store cash and valuables, as queried in property and cash-shortage insurance proposal forms to set sum-insured limits for stored values.",
      "synonyms": [
        "Safe resistance grade",
        "Vault classification"
      ],
      "linesOfBusiness": [
        "Property",
        "Liability"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Security",
        "Cash security",
        "Underwriting"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-security-concept"
        ],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks",
          "cov-mankoversicherung"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-mechanical-security"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "security",
        "dataType": "enum",
        "questions": [
          "What is the certified resistance grade of the safe, strongroom or vault used to store cash and valuables (e.g. EN 1143-1 grade)?",
          "Is the unit anchored to the building structure in accordance with the manufacturer's and certifier's specifications?",
          "What is the maximum cash or valuables sum kept in the unit outside business hours?"
        ],
        "evidence": [
          "Safe / strongroom certification plate and certificate",
          "Anchoring installation confirmation",
          "Cash-holding policy documenting overnight sum limits"
        ],
        "riskDrivers": [
          "severity",
          "accumulation"
        ],
        "ratingImpact": [
          "sublimit",
          "premium",
          "condition"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "EN 1143-1 – Secure storage units, Requirements, classification and methods of test for resistance to burglary, Part 1: Safes, ATM safes, strongroom doors and strongrooms"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/safe-security-rating/",
      "alternateUrl": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/wertschutzschrank-und-sicherungsklasse/",
      "body": "## Why it matters for underwriting\n\nThe certified resistance grade of a safe or strongroom is the single measure that ties an insurer's cash and valuables sublimit to a verifiable physical control, because burglars who reach a safe typically have a fixed amount of uninterrupted time before an alarm response arrives, and a unit's resistance grade directly indicates how long it can withstand mechanical or thermal attack tools within that window. Underwriters use the grade, together with the amount of value actually kept overnight or over weekends, to set sum-insured limits for cash-in-safe and to price the account relative to peers with comparable exposure; a mismatch between the value stored and the grade of the unit protecting it is one of the most common causes of coverage disputes after a burglary loss.\n\n## Capturing the attribute and evidence\n\nProposal forms ask for the certified resistance grade of the unit (typically referenced against EN 1143-1 or an equivalent national classification), confirmation that the unit is anchored to the building structure as required for its weight class, and the maximum sum of cash or valuables the business intends to keep in the unit outside business hours. Underwriters verify the declaration against the certification plate and accompanying certificate issued at installation, and against an anchoring confirmation where the unit's weight requires fixing to the floor or wall; a documented cash-holding policy setting an internal overnight limit is typically requested for higher sums insured.\n\n## Effect on coverage, premium and conditions\n\nA resistance grade that comfortably exceeds the value habitually stored, combined with proper anchoring, supports higher cash-in-safe sublimits and more favourable premium terms. A unit with an inadequate grade for the value stored, a freestanding unit that should be anchored but is not, or holdings that regularly exceed the sublimit implied by the grade commonly result in reduced sublimits, warranties capping the overnight cash holding, or deductible loadings on burglary and cash-shortage claims.\n\n## Mitigation measures\n\nWhere the grade is insufficient for the value habitually stored, insurers and risk engineers typically recommend upgrading to a higher-rated unit matched to the actual exposure, ensuring anchoring meets the manufacturer's specification for the unit's weight class, and formalising an internal policy that caps cash and valuables held in the unit outside business hours to a level consistent with its certified grade."
    },
    "de": {
      "id": "ra-safe-security-rating",
      "lang": "de",
      "type": "risk-attribute",
      "title": "Wertschutzschrank- und Sicherungsklasse",
      "shortDefinition": "Die Wertschutzschrank- und Sicherungsklasse erfasst den zertifizierten Widerstandsgrad eines Wertschutzschranks, Tresorraums oder Tresors zur Aufbewahrung von Bargeld und Wertsachen – eine in Sach- und Mankoversicherungsanträgen abgefragte Angabe zur Festlegung von Versicherungssummen für hinterlegte Werte.",
      "synonyms": [
        "Widerstandsgrad des Wertschutzschranks",
        "Tresorklassifizierung"
      ],
      "linesOfBusiness": [
        "Sach",
        "Haftpflicht"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Sicherheitstechnik",
        "Bargeldsicherheit",
        "Underwriting"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-security-concept"
        ],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks",
          "cov-mankoversicherung"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-mechanical-security"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "security",
        "dataType": "enum",
        "questions": [
          "Welchen zertifizierten Widerstandsgrad weist der zur Aufbewahrung von Bargeld und Wertsachen genutzte Wertschutzschrank, Tresorraum oder Tresor auf (z.B. Widerstandsgrad nach EN 1143-1)?",
          "Ist das Behältnis gemäss den Vorgaben von Hersteller und Zertifizierungsstelle am Baukörper verankert?",
          "Welcher maximale Bargeld- oder Wertsachenbestand wird ausserhalb der Geschäftszeiten im Behältnis aufbewahrt?"
        ],
        "evidence": [
          "Zertifizierungsplakette und Zertifikat des Wertschutzschranks / Tresorraums",
          "Bestätigung der Verankerung",
          "Bargeldbestandsrichtlinie mit Obergrenze für den Übernachtbestand"
        ],
        "riskDrivers": [
          "severity",
          "accumulation"
        ],
        "ratingImpact": [
          "sublimit",
          "premium",
          "condition"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [
        "EN 1143-1 – Wertbehältnisse, Anforderungen, Klassifizierung und Prüfverfahren für die Widerstandsfähigkeit gegen Einbruchdiebstahl, Teil 1: Wertschutzschränke, Geldautomatentresore, Tresorraumtüren und Tresorräume"
      ],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/wertschutzschrank-und-sicherungsklasse/",
      "alternateUrl": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/safe-security-rating/",
      "body": "## Warum relevant für das Underwriting\n\nDer zertifizierte Widerstandsgrad eines Wertschutzschranks oder Tresorraums ist die massgebliche Grösse, die eine Sublimite für Bargeld und Wertsachen mit einer nachprüfbaren physischen Kontrolle verknüpft, denn Täter, die einen Wertschutzschrank erreichen, verfügen typischerweise nur über eine begrenzte, ungestörte Zeitspanne bis zum Eintreffen einer Intervention, und der Widerstandsgrad des Behältnisses gibt unmittelbar Auskunft darüber, wie lange es mechanischen oder thermischen Angriffswerkzeugen innerhalb dieses Zeitfensters widersteht. Underwriter nutzen den Widerstandsgrad zusammen mit dem tatsächlich über Nacht oder über das Wochenende aufbewahrten Wert, um Versicherungssummen für Bargeld im Schrank festzulegen und das Risiko im Vergleich zu Betrieben mit ähnlicher Exposition zu bepreisen; ein Missverhältnis zwischen dem gelagerten Wert und dem Widerstandsgrad des schützenden Behältnisses zählt zu den häufigsten Ursachen für Deckungsstreitigkeiten nach einem Einbruchschaden.\n\n## Erfassung und Nachweise\n\nAntragsformulare fragen nach dem zertifizierten Widerstandsgrad des Behältnisses (üblicherweise mit Bezug auf EN 1143-1 oder eine gleichwertige nationale Klassifizierung), der Bestätigung, dass das Behältnis gemäss den Anforderungen seiner Gewichtsklasse am Baukörper verankert ist, sowie dem Höchstbetrag an Bargeld oder Wertsachen, den das Unternehmen ausserhalb der Geschäftszeiten im Behältnis aufzubewahren beabsichtigt. Underwriter prüfen die Angabe anhand der bei Installation ausgestellten Zertifizierungsplakette und des zugehörigen Zertifikats sowie anhand einer Verankerungsbestätigung, sofern das Gewicht des Behältnisses eine Befestigung am Boden oder an der Wand erfordert; für höhere Versicherungssummen wird üblicherweise eine dokumentierte Bargeldbestandsrichtlinie mit interner Obergrenze für den Übernachtbestand verlangt.\n\n## Wirkung auf Deckung, Prämie und Bedingungen\n\nEin Widerstandsgrad, der den üblicherweise gelagerten Wert deutlich übersteigt, führt in Verbindung mit ordnungsgemässer Verankerung zu höheren Sublimiten für Bargeld im Schrank und zu günstigeren Prämienkonditionen. Ein für den gelagerten Wert unzureichender Widerstandsgrad, ein freistehendes Behältnis, das eigentlich verankert sein müsste, oder ein Bestand, der die durch den Widerstandsgrad implizierte Sublimite regelmässig übersteigt, führen häufig zu reduzierten Sublimiten, zu Obliegenheiten mit einer Obergrenze für den Übernachtbestand oder zu Selbstbehaltszuschlägen bei Einbruch- und Mankoschäden.\n\n## Massnahmen\n\nIst der Widerstandsgrad für den üblicherweise gelagerten Wert unzureichend, empfehlen Versicherer und Risk Engineers üblicherweise die Umrüstung auf ein höherklassifiziertes Behältnis, das der tatsächlichen Exposition entspricht, die Sicherstellung einer den Herstellervorgaben entsprechenden Verankerung für die jeweilige Gewichtsklasse sowie die Formalisierung einer internen Richtlinie, die den ausserhalb der Geschäftszeiten im Behältnis aufbewahrten Bargeld- und Wertsachenbestand auf ein mit dem zertifizierten Widerstandsgrad vereinbares Niveau begrenzt."
    }
  }
}