  "id": "ra-lightning-protection-system",
  "type": "risk-attribute",
  "languages": {
    "en": {
      "id": "ra-lightning-protection-system",
      "lang": "en",
      "type": "risk-attribute",
      "title": "Lightning Protection System",
      "shortDefinition": "Lightning protection system confirms whether a building and its electrical and electronic installations are protected by an external and internal lightning protection system, as queried in property and electronic equipment insurance proposal forms.",
      "synonyms": [
        "External and internal lightning protection"
      ],
      "linesOfBusiness": [
        "Property",
        "Engineering Insurance"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Fire protection",
        "Underwriting"
      ],
      "relations": {
        "relatedTerms": [],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks",
          "cov-elektronikversicherung"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-lightning-protection"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "fire-protection",
        "dataType": "boolean",
        "questions": [
          "Is the building fitted with an external lightning protection system (air-termination, down-conductors, earthing) matching its lightning protection level?",
          "Is internal lightning and surge protection installed to protect electrical and electronic installations against transient overvoltage?",
          "When was the system last inspected, and are inspection intervals aligned with the risk class of the building and its contents?"
        ],
        "evidence": [
          "Lightning protection system design documentation",
          "Inspection and test reports",
          "Surge protection device installation records"
        ],
        "riskDrivers": [
          "severity",
          "frequency"
        ],
        "ratingImpact": [
          "premium",
          "condition",
          "exclusion"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/lightning-protection-system/",
      "alternateUrl": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/blitzschutzanlage/",
      "body": "## Why it matters for underwriting\n\nA direct or nearby lightning strike can ignite a fire, damage structural elements, and, through the associated surge, destroy electrical and electronic equipment across an entire installation almost instantaneously. Because lightning risk correlates with location (exposed sites, tall structures, elevated terrain) and occupancy (electronics-heavy operations, flammable storage), underwriters use the presence and design level of lightning protection to differentiate accounts that share similar construction and use but face materially different loss potential from this single peril.\n\n## Capturing the attribute and evidence\n\nProposal forms ask whether an external system (air-termination network, down-conductors, earthing) and internal surge protection are installed, and to which lightning protection level the system was designed. Underwriters look for the design documentation specifying the protection level chosen for the building's risk class, inspection and test reports confirming earthing resistance and conductor continuity, and records of surge protection devices installed at incoming electrical and data lines.\n\n## Effect on coverage, premium and conditions\n\nA correctly designed, regularly inspected lightning protection system, including surge protection for sensitive equipment, supports standard rating and is generally required by insurers to maintain full electronic equipment coverage without added deductibles. Missing or outdated systems, particularly the absence of internal surge protection, often lead to a condition requiring installation, higher deductibles for lightning and surge losses, or, for electronics-heavy risks, a specific exclusion until remediated.\n\n## Mitigation measures\n\nWhere lightning protection is absent, undersized or unmaintained, insurers and risk engineers typically recommend installing an external system designed to the appropriate protection level for the building's risk class, fitting coordinated surge protection devices at all electrical and data entry points, and establishing a regular inspection and test programme covering earthing resistance and conductor continuity."
    },
    "de": {
      "id": "ra-lightning-protection-system",
      "lang": "de",
      "type": "risk-attribute",
      "title": "Blitzschutzanlage",
      "shortDefinition": "Die Blitzschutzanlage bestätigt, ob ein Gebäude sowie dessen elektrische und elektronische Installationen durch einen äusseren und inneren Blitzschutz geschützt sind – eine in Sach- und Elektronikversicherungs- anträgen regelmässig abgefragte Angabe.",
      "synonyms": [
        "Äusserer und innerer Blitzschutz"
      ],
      "linesOfBusiness": [
        "Sach",
        "Technische Versicherung"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Brandschutz",
        "Underwriting"
      ],
      "relations": {
        "relatedTerms": [],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks",
          "cov-elektronikversicherung"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-lightning-protection"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "fire-protection",
        "dataType": "boolean",
        "questions": [
          "Ist das Gebäude mit einem äusseren Blitzschutz (Fangeinrichtung, Ableitungen, Erdung) ausgestattet, der der massgebenden Blitzschutzklasse entspricht?",
          "Ist ein innerer Blitz- und Überspannungsschutz zum Schutz elektrischer und elektronischer Installationen vor transienten Überspannungen installiert?",
          "Wann wurde die Anlage zuletzt geprüft, und sind die Prüfintervalle auf die Risikoklasse des Gebäudes und seiner Einrichtung abgestimmt?"
        ],
        "evidence": [
          "Auslegungsunterlagen der Blitzschutzanlage",
          "Prüf- und Messberichte",
          "Nachweise zur Installation von Überspannungsschutzgeräten"
        ],
        "riskDrivers": [
          "severity",
          "frequency"
        ],
        "ratingImpact": [
          "premium",
          "condition",
          "exclusion"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/blitzschutzanlage/",
      "alternateUrl": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/lightning-protection-system/",
      "body": "## Warum relevant für das Underwriting\n\nEin direkter oder naher Blitzeinschlag kann einen Brand auslösen, bauliche Elemente beschädigen und durch die damit verbundene Überspannung elektrische und elektronische Anlagen in einer gesamten Installation nahezu augenblicklich zerstören. Da das Blitzrisiko stark vom Standort (exponierte Lagen, hohe Bauwerke, erhöhtes Gelände) und von der Nutzung (elektronikintensive Betriebe, brennbare Lagerung) abhängt, nutzen Underwriter das Vorhandensein und die Auslegungsklasse des Blitzschutzes, um Betriebe mit ähnlicher Bauart und Nutzung, aber deutlich unterschiedlichem Schadenpotenzial aus dieser einzelnen Gefahr zu unterscheiden.\n\n## Erfassung und Nachweise\n\nAntragsformulare fragen, ob ein äusseres System (Fangeinrichtung, Ableitungen, Erdung) und ein innerer Überspannungsschutz installiert sind und nach welcher Blitzschutzklasse die Anlage ausgelegt wurde. Underwriter prüfen die Auslegungsunterlagen mit der für die Risikoklasse des Gebäudes gewählten Schutzklasse, Prüf- und Messberichte zum Erdungswiderstand und zur Durchgängigkeit der Ableitungen sowie Nachweise über installierte Überspannungsschutzgeräte an eingehenden Strom- und Datenleitungen.\n\n## Wirkung auf Deckung, Prämie und Bedingungen\n\nEine korrekt ausgelegte, regelmässig geprüfte Blitzschutzanlage inklusive Überspannungsschutz für empfindliche Anlagen unterstützt eine normale Prämienbildung und wird von Versicherern häufig als Voraussetzung für vollen Elektronikversicherungsschutz ohne zusätzliche Selbstbehalte verlangt. Fehlende oder veraltete Anlagen, insbesondere das Fehlen eines inneren Überspannungsschutzes, führen häufig zu einer Auflage zur Nachrüstung, zu höheren Selbstbehalten für Blitz- und Überspannungsschäden oder bei elektronikintensiven Risiken bis zur Nachbesserung zu einem spezifischen Ausschluss.\n\n## Massnahmen\n\nFehlt ein Blitzschutz, ist er unterdimensioniert oder unzureichend gewartet, empfehlen Versicherer und Risk Engineers üblicherweise die Errichtung einer äusseren Anlage nach der für die Risikoklasse des Gebäudes passenden Schutzklasse, die Installation aufeinander abgestimmter Überspannungsschutzgeräte an allen Strom- und Dateneintrittspunkten sowie die Einführung eines regelmässigen Prüfprogramms für Erdungswiderstand und Ableitungsdurchgängigkeit."
    }
  }
}