  "id": "ra-fire-compartmentation-building",
  "type": "risk-attribute",
  "languages": {
    "en": {
      "id": "ra-fire-compartmentation-building",
      "lang": "en",
      "type": "risk-attribute",
      "title": "Fire Compartmentation",
      "shortDefinition": "Fire compartmentation records how a building is subdivided into fire-resistant sections, and is queried in property proposal forms to assess how effectively a fire can be contained before it spreads.",
      "synonyms": [
        "Fire separation",
        "Compartment size"
      ],
      "linesOfBusiness": [
        "Property"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Building",
        "Fire protection"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-fire-compartmentation",
          "riskg-firewalls"
        ],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-fire-compartmentation",
          "riskg-firewalls"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "building",
        "dataType": "enum",
        "questions": [
          "Is the building subdivided into fire compartments, and what is the maximum compartment area or fire-resistance rating (e.g. EI 90, REI 120)?",
          "Are firewalls carried through the full height and depth of the building, including roof and basement levels?",
          "Are openings in fire-separating walls (doors, ducts, cable penetrations) fitted with fire-rated closures and dampers?"
        ],
        "evidence": [
          "Fire safety concept or compartmentation plan",
          "Building permit documentation",
          "Risk engineering survey report"
        ],
        "riskDrivers": [
          "severity",
          "accumulation"
        ],
        "ratingImpact": [
          "premium",
          "sublimit",
          "condition"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/fire-compartmentation-building/",
      "alternateUrl": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/bauliche-brandabschnittsbildung/",
      "body": "## Why it matters for underwriting\n\nFire compartmentation determines how large an area a single fire event can affect before fire-resistant construction stops or slows its spread. It is the primary structural counterpart to active protection such as sprinklers: even a well-sprinklered building can suffer a large loss if compartment walls are undersized, breached by unsealed openings, or do not extend fully through roof voids and risers. Underwriters use declared compartment size and rating to estimate the maximum single-event loss and to set accumulation limits relative to the sum insured at a location.\n\n## Capturing the attribute and evidence\n\nProposal forms ask whether the building is compartmentalised, the maximum area of a single compartment, and the fire-resistance rating of separating walls and floors. The fire safety concept, compartmentation plan and, for larger risks, a risk engineering survey confirm not only the design rating but also whether openings such as doors, cable and pipe penetrations are properly fire-stopped, since unsealed penetrations are a common cause of compartmentation failure in practice.\n\n## Effect on coverage, premium and conditions\n\nWell-defined, adequately rated compartments with properly sealed openings support lower premium rates and higher single-location sublimits. Large undivided areas, compartment walls that stop short of the roof deck, or evidence of unsealed penetrations typically trigger rate loadings, reduced sublimits on accumulation, or a condition requiring remediation of identified compartmentation gaps within a defined period.\n\n## Mitigation measures\n\nWhere compartmentation is inadequate, insurers typically recommend extending fire-resistant walls to the required rating and full building depth, fire-stopping all service penetrations, fitting self-closing fire doors and dampers, and periodically inspecting compartment integrity."
    },
    "de": {
      "id": "ra-fire-compartmentation-building",
      "lang": "de",
      "type": "risk-attribute",
      "title": "Bauliche Brandabschnittsbildung",
      "shortDefinition": "Die bauliche Brandabschnittsbildung erfasst, wie ein Gebäude in feuerwiderstandsfähige Abschnitte unterteilt ist, und wird in Sachversicherungsanträgen abgefragt, um zu beurteilen, wie wirksam ein Brand eingegrenzt werden kann, bevor er sich ausbreitet.",
      "synonyms": [
        "Brandabschnittsgrösse",
        "Brandtrennung"
      ],
      "linesOfBusiness": [
        "Sach"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Gebäude",
        "Brandschutz"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-fire-compartmentation",
          "riskg-firewalls"
        ],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-fire-compartmentation",
          "riskg-firewalls"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "building",
        "dataType": "enum",
        "questions": [
          "Ist das Gebäude in Brandabschnitte unterteilt, und welche maximale Abschnittsfläche bzw. Feuerwiderstandsklasse (z.B. EI 90, REI 120) gilt?",
          "Sind Brandmauern über die gesamte Höhe und Tiefe des Gebäudes durchgehend, einschliesslich Dach- und Untergeschossbereich?",
          "Sind Öffnungen in Brandtrennwänden (Türen, Kanäle, Kabeldurchführungen) mit feuerwiderstandsfähigen Verschlüssen und Brandschutzklappen ausgerüstet?"
        ],
        "evidence": [
          "Brandschutzkonzept oder Abschnittsbildungsplan",
          "Baubewilligungsunterlagen",
          "Risk-Engineering-Begehungsbericht"
        ],
        "riskDrivers": [
          "severity",
          "accumulation"
        ],
        "ratingImpact": [
          "premium",
          "sublimit",
          "condition"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/bauliche-brandabschnittsbildung/",
      "alternateUrl": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/fire-compartmentation-building/",
      "body": "## Warum relevant für das Underwriting\n\nDie bauliche Brandabschnittsbildung bestimmt, wie gross die Fläche sein kann, die ein einzelnes Brandereignis erfasst, bevor eine feuerwiderstandsfähige Bauweise die Ausbreitung stoppt oder verzögert. Sie ist das wichtigste bauliche Gegenstück zu aktiven Schutzmassnahmen wie Sprinkleranlagen: Selbst ein gut gesprinklertes Gebäude kann einen Grossschaden erleiden, wenn Brandwände zu klein dimensioniert oder durch unversiegelte Öffnungen unterbrochen sind. Underwriter nutzen die deklarierte Abschnittsgrösse und Feuerwiderstandsklasse, um den maximalen Einzelschaden abzuschätzen und Kumullimiten im Verhältnis zur Versicherungssumme eines Standorts festzulegen.\n\n## Erfassung und Nachweise\n\nAntragsformulare fragen, ob das Gebäude in Abschnitte unterteilt ist, wie gross die maximale Fläche eines einzelnen Abschnitts ist und welche Feuerwiderstandsklasse Trennwände und Decken aufweisen. Das Brandschutzkonzept, der Abschnittsbildungsplan und – bei grösseren Risiken – eine Risk-Engineering-Begehung bestätigen nicht nur die Planwerte, sondern auch, ob Öffnungen wie Türen, Kabel- und Rohrdurchführungen sachgerecht abgeschottet sind, da unversiegelte Durchführungen eine häufige Ursache für das Versagen der Abschnittsbildung sind.\n\n## Wirkung auf Deckung, Prämie und Bedingungen\n\nKlar definierte, ausreichend klassifizierte Abschnitte mit sachgerecht abgeschotteten Öffnungen unterstützen tiefere Prämiensätze und höhere Sublimiten pro Standort. Grosse, nicht unterteilte Flächen, Brandwände, die nicht bis zur Dachhaut durchgeführt sind, oder Hinweise auf unversiegelte Durchführungen führen üblicherweise zu Prämienzuschlägen, reduzierten Kumul-Sublimiten oder einer Bedingung, festgestellte Mängel in der Abschnittsbildung innerhalb einer definierten Frist zu beheben.\n\n## Massnahmen\n\nIst die Abschnittsbildung unzureichend, empfehlen Versicherer und Risk Engineers üblicherweise den Einbau oder die Ergänzung feuerwiderstandsfähiger Wände in der erforderlichen Klasse und über die gesamte Gebäudetiefe, die brandschutztechnische Abschottung aller Leitungsdurchführungen, den Einbau selbstschliessender Brandschutztüren und -klappen sowie die periodische Kontrolle der Abschnittsintegrität im Rahmen der laufenden Instandhaltung."
    }
  }
}