  "id": "ra-facade-material",
  "type": "risk-attribute",
  "languages": {
    "en": {
      "id": "ra-facade-material",
      "lang": "en",
      "type": "risk-attribute",
      "title": "Facade Material",
      "shortDefinition": "Facade material records the composition and fire classification of a building's external wall cladding and insulation, and is queried in property proposal forms because combustible facades enable rapid, hard-to-suppress vertical fire spread.",
      "synonyms": [
        "Cladding material",
        "External wall insulation system"
      ],
      "linesOfBusiness": [
        "Property"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Building",
        "Fire protection"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-flammable-facades"
        ],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-flammable-facades"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "building",
        "dataType": "text",
        "questions": [
          "What is the outer cladding material of the facade, and what is its fire classification?",
          "Does the facade include an external thermal insulation composite system (ETICS), and if so, what insulation material and cladding is used?",
          "Is there a cavity behind the cladding, and if so, are cavity barriers installed to prevent chimney-effect fire spread?"
        ],
        "evidence": [
          "Facade construction specification",
          "Fire classification certificate for cladding and insulation",
          "Risk engineering survey report"
        ],
        "riskDrivers": [
          "severity",
          "accumulation"
        ],
        "ratingImpact": [
          "premium",
          "condition",
          "exclusion"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/facade-material/",
      "alternateUrl": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/fassadenmaterial/",
      "body": "## Why it matters for underwriting\n\nFacade material has become one of the fastest-growing concerns in property underwriting following high-profile total losses in which combustible cladding or insulation allowed a small fire to spread vertically across an entire building face within minutes, far outpacing sprinkler protection and firefighting response designed around internal fire spread assumptions. Underwriters need to know the cladding material, the insulation behind it, and whether the assembly is tested and classified as a system, because individually non-combustible components can still form a combustible assembly in certain cavity configurations.\n\n## Capturing the attribute and evidence\n\nProposal forms ask for the cladding material, whether an external thermal insulation composite system is present, the insulation type, and whether cavity barriers are installed to interrupt chimney-effect fire spread within ventilated facades. Facade construction specifications and fire classification certificates for the tested assembly, not just individual components, are the key evidence, supplemented by a risk engineering survey where cladding history is unclear.\n\n## Effect on coverage, premium and conditions\n\nFacades built from non-combustible materials with a classified, tested assembly generally support standard terms. Combustible cladding, unclassified insulation systems, or facades where cavity barriers cannot be confirmed frequently trigger premium loadings, sublimits on fire damage, remediation conditions, or in severe cases exclusion of facade-related fire spread or declinature until the cladding is replaced.\n\n## Mitigation measures\n\nWhere combustible facade materials are identified, insurers typically recommend replacing cladding and insulation with classified non-combustible alternatives, retrofitting cavity barriers to limit chimney-effect spread, and obtaining independent assessment of the installed assembly, since laboratory classifications for individual products do not always reflect real-world installation quality."
    },
    "de": {
      "id": "ra-facade-material",
      "lang": "de",
      "type": "risk-attribute",
      "title": "Fassadenmaterial",
      "shortDefinition": "Das Fassadenmaterial erfasst die Zusammensetzung und Brandklassifizierung der Aussenwandverkleidung und -dämmung eines Gebäudes und wird in Sachversicherungsanträgen abgefragt, weil brennbare Fassaden eine rasche, schwer zu bekämpfende vertikale Brandausbreitung ermöglichen.",
      "synonyms": [
        "Verkleidungsmaterial",
        "Wärmedämmverbundsystem"
      ],
      "linesOfBusiness": [
        "Sach"
      ],
      "jurisdictions": [
        "CH",
        "EU",
        "Global"
      ],
      "tags": [
        "Gebäude",
        "Brandschutz"
      ],
      "relations": {
        "relatedTerms": [
          "riskg-flammable-facades"
        ],
        "partOf": [],
        "appliesTo": [],
        "regulatedBy": [],
        "relevantFor": [
          "cov-property-all-risks"
        ],
        "insurableVia": [],
        "mitigatedBy": [
          "riskg-flammable-facades"
        ],
        "comprises": [],
        "alternativeTo": [],
        "complementedBy": []
      },
      "attribute": {
        "category": "building",
        "dataType": "text",
        "questions": [
          "Aus welchem Material besteht die äussere Fassadenverkleidung und welche Brandklassifizierung hat sie?",
          "Verfügt die Fassade über ein Wärmedämmverbundsystem (WDVS), und wenn ja, welches Dämm- und Verkleidungsmaterial wird verwendet?",
          "Besteht hinter der Verkleidung ein Hohlraum, und wenn ja, sind Brandsperren eingebaut, um eine Kaminwirkung bei der Brandausbreitung zu verhindern?"
        ],
        "evidence": [
          "Fassadenkonstruktionsspezifikation",
          "Brandklassifizierungszertifikat für Verkleidung und Dämmung",
          "Risk-Engineering-Begehungsbericht"
        ],
        "riskDrivers": [
          "severity",
          "accumulation"
        ],
        "ratingImpact": [
          "premium",
          "condition",
          "exclusion"
        ]
      },
      "profile": null,
      "coverageProfile": null,
      "clause": null,
      "legalBasis": [],
      "standards": [],
      "reviewStatus": "expert-reviewed",
      "reviewedBy": "Guido Hesse, Hesse Group Holding AG",
      "lastReviewed": "2026-09-04",
      "version": "0.1.0",
      "updated": "2026-09-03",
      "generated": {
        "by": "cursor-agent/claude-sonnet-5",
        "at": "2026-09-03T00:00:00.000Z"
      },
      "verified": [
        {
          "by": "human:ghesse",
          "at": "2026-09-04T00:00:00.000Z",
          "method": null
        }
      ],
      "staleAfter": null,
      "url": "https://hgh.ch/lexikon/de/wissen/risikomerkmal/fassadenmaterial/",
      "alternateUrl": "https://hgh.ch/lexikon/en/knowledge/risk-attribute/facade-material/",
      "body": "## Warum relevant für das Underwriting\n\nDas Fassadenmaterial ist im Sach-Underwriting zu einem der am schnellsten wachsenden Themenfelder geworden, seit mehrere aufsehenerregende Grossschäden zeigten, dass brennbare Verkleidungen oder Dämmstoffe einen kleinen Brand innerhalb von Minuten über die gesamte Gebäudefassade ausbreiten lassen können – weit schneller, als es Sprinklerschutz und Feuerwehreinsätze bewältigen können, die auf Annahmen zur internen Brandausbreitung ausgelegt sind. Underwriter müssen das Verkleidungsmaterial, die dahinterliegende Dämmung und wissen, ob die Konstruktion als Gesamtsystem geprüft und klassifiziert wurde, da einzeln nichtbrennbare Komponenten in Kombination mit bestimmten Hohlraumkonfigurationen dennoch eine brennbare Gesamtkonstruktion ergeben können.\n\n## Erfassung und Nachweise\n\nAntragsformulare fragen nach dem Verkleidungsmaterial, ob ein Wärmedämmverbundsystem vorhanden ist, welche Dämmart verwendet wird und ob Brandsperren eingebaut sind, um eine Kaminwirkung in hinterlüfteten Fassaden zu unterbrechen. Fassadenkonstruktionsspezifikationen und Brandklassifizierungszertifikate für die geprüfte Gesamtkonstruktion – nicht nur für Einzelkomponenten – sind die wichtigsten Nachweise, ergänzt durch eine Risk-Engineering-Begehung bei Gebäuden, deren Fassadenhistorie oder Renovationsunterlagen unklar sind.\n\n## Wirkung auf Deckung, Prämie und Bedingungen\n\nFassaden aus nichtbrennbaren Materialien mit einer klassifizierten, geprüften Gesamtkonstruktion unterstützen in der Regel Standardbedingungen. Brennbare Verkleidungen, nicht klassifizierte Dämmverbundsysteme oder Fassaden, bei denen Brandsperren nicht nachgewiesen werden können, führen häufig zu Prämienzuschlägen, Sublimiten für Brandschäden, Auflagen zur Behebung innerhalb einer definierten Frist oder in schweren Fällen zum Ausschluss fassadenbedingter Brandausbreitung bzw. zur Ablehnung bis zum Austausch der Verkleidung.\n\n## Massnahmen\n\nWerden brennbare Fassadenmaterialien festgestellt, empfehlen Versicherer und Risk Engineers üblicherweise den Ersatz von Verkleidung und Dämmung durch klassifizierte nichtbrennbare Alternativen, die Nachrüstung von Brandsperren zur Begrenzung der Kaminwirkung sowie eine unabhängige brandschutztechnische Beurteilung der tatsächlich eingebauten Konstruktion, da Laborklassifizierungen einzelner Produkte die reale Einbauqualität nicht immer widerspiegeln."
    }
  }
}